Please enable JavaScript to view this site.

TEMES 1.0

Navigation: Devices > SICOLOG > Additional TEMES Parameters

Extended Logging of Start and Stop Events

Scroll Prev Top Next More

The extended logging of start and stop events can be activated with

 

LogMode = 1

 

where LogMode represents an integer number with the following meaning:

 

0: Disabled (default)

1: Extended logging of the first start events after a new configuration has been loaded

2: Extended logging of all start events

3: Extended logging of all start and stop events (Stop events are not reported by TEMES V1.0.91)

 

The log is enclosed in the measurement variable Measurement.M1.info. The extended logging of start events includes the fast sample index, the device number, the device version number, the timestamp, the timezone, and the supplying voltage of the SICOLOG. The extended logging of stop events includes the fast sample index, the timestamp, the timezone, and the supplying voltage of the SICOLOG.

 

ATTENTION: When using a LogMode greater than 0, then at least TEMES V1.0.91 is required to read the measurement.

 

Minimum required versions: SICOLOG V1.0.44 / TEMES V1.0.92 / TSD.EXE V1.13