The module CANSIG extracts a physical signal out of a bit value.

 

Arg

Description

0

Name of the input signal x

1

reserved

2

reserved

3

reserved

4

Type (0 – Intel unsigned, 1 – Intel signed, 2 – Motorola unsigned, 3 – Motorola signed)

5

Start bit

6

Bit length

7

Factor

8

Offset

9

Unit

10

Min

11

Max

12

ModeType

13

ModeStartBit

14

ModeBitLength

15

ModeId